WBE Double Doors High-Temperature Test Chamber: This test exposes samples to a high-temperature, dry environment to determine the suitability of military/civilian equipment for storage and operation under high-temperature conditions. It is used for screening, aging tests, life tests, accelerated life tests, and evaluation tests of LEDs, components, and complete machines, and plays an important role in the verification of failure analysis.
Application areas:
production design, improvement, evaluation and inspection in defense industry, aerospace industry, automation components, automotive parts, electronic and electrical components, plastics, chemicals, textiles and other fields. ...
Double Doors High Temperature Test Chamber Feature:
- GB/T3512-2014/ISO 188:2011 Culcanized rubber or thermoplastic rubber—Accelerated aging and heat resistance tests in hot air
- GB/T9871-2008/S06914:2014 Determination of aging properties of culcanized rubber or thermoplastic rubber—Tensile stress relaxation test
- GB/T2951.12-2008/EC60811-1-2:1985 General test methods for insulation and sheathing materials of cables and optical fibers—Part 12: General test methods—Thermal aging test methods
- JB/T 4278.6-2011 Verification methods for testing instruments and equipment for rubber and plastic wires and cables—Part 6: Natural ventilation thermal aging test chamber
- JB/T7444-2018 Chamber air thermal aging test chamber
- GB, VDE, JIS and other test requirements
- GB/T 7141-2008 Plastics thermal aging test methods
Chamber Parameter
| Model |
WBE-GW1000L A/B/D |
WBE-GW1500L A/B/D |
WBE-GW2250L A/B/D |
WBE-GW3000L A/B/D |
WBE-GW4950L A/B/D |
| Volume(L) |
1000 L |
1500 L |
2250 L |
3000 L |
4950 L |
| Inner Size(mm) |
Width |
1000 |
1000 |
1500 |
2000 |
2200 |
| Depth |
1000 |
1000 |
1000 |
1000 |
1500 |
| eightH |
1000 |
1500 |
1500 |
1500 |
1500 |
| Outer Size(mm) |
Width |
1400 |
1400 |
2100 |
2600 |
2600 |
| Depth |
1200 |
1450 |
1200 |
1200 |
1900 |
| eightH |
1730 |
2280 |
2200 |
2200 |
2080 |
| Power |
AC380V±10% 50HZ 3∮4W+E |
| Performance |
Temp Range |
A:RT+15℃~+150℃,B:RT+15℃~+250℃,D:RT+15℃~+300℃ |
| Temp Fluctuation |
≤±0.5℃ |
| Temp Uniformity |
≤2.0℃% |
| Temp Deviation |
≤±2.0℃% |
| Heating Rate |
≥5℃/min (average over full range) |
| Material |
Inner Chamber |
SUS #304 Stainless Steel |
| External Chamber |
Cold-rolled steel plate + double-sided electrostatic spray coating process, WBE Weibang Standard Blue-Gray |
| Cooling Method |
Natural cooling / Forced ventilation cooling |